					 25MHz, ALT Trigger. 
  1mV sensitivity. 
  10ns Resolution. 
  Component test, Beam-finder 
  Illuminate, Hold-off, X-Y  
SPECIFICATIONS CRT:  Type: Rectangular with integral grateful.  Display Area: 8 x 10 div (1 div= 1 cm)  Accelerating Voltage: 2.1 kV.  Phosphor: P31  Vertical amplifiers (CH 1 and CH 2)  Sensitivity: 5 mV/div to 5V/div (X1 mode).                        1 mV/div to 1V/div (X5 mode).                        1-2-5 sequence, 10 step attenuator.                        Vernier control provides full adjustable                         attenuation between steps.  Accuracy: ±3% (X1 mode). ±5% (X5 mode).  Input Resistance: 1 M±2%  Input Capacitance: 25 pF//10pF.  Frequency Response: 5 mV to 5 V/div (CAL): DC                                           to 25 MHz (-3 dB) 1 mV/div                                           (CAL): DC to 10 MHz (-3 dB)  Rise Time: Approximately 14.0ns.  Operating Modes: CH1 : CH 1, single trace. CH2 : CH 2,                                    single trace. ALT : dual trace, alternating.                                    CHOP : dual trace, chopped. ADD :                                   algebraic sum of CH 1 + CH 2  Polarity Reversal (Invert): CH 2 only.  Maximum Input Voltage: 400 V dv + ac peak  Maximum Undistorted Amplitude: DC-to-25 MHz : 4 divisions.                                                                  DC-to-15 MHz : 8 divisions.  HORIZONTAL AMPLIFIER (Input through channel 1 input)  X-Y mode : switch selectable using X-Y switch.                        CH 1 : X axis CH 2 : Y axis  Sensitivity: 1mv/div to 5v/div  Accuracy: Y-Axis : ±3% ±X-Axis : ±6%  Input Impedance: 1M//25PF  Frequency Response: DC to 1 MHz typical (-3 dB)  X-Y Phase Difference: Approximately 3o at 50 kHz.  Maximum input Voltage: 400Vdc+ac peak  SWEEP SYSTEM  Sweep Speed: 0.1 μs/div to 2 s/div in 1-2-5 sequence,                            23 steps. Vernier control provides fully                            adjustable sweep time between steps.  Accuracy : ±3%  Sweep Magnification:10X, ±6% (0.1 μs and 0.2 μs ranges                                           uncaliubrated when X10 is engaged).  Holdoff: Continuously adjustable from NORM to 5 times normal.  TRIGGERING  Trigger Source: CH 1, CH 2, ALT, EXT, LINE.  Maximum External Trigger Voltage: 300V dc + ac peak.  Trigger Coupling: AC: 30 Hz to 30 MHz TV - H : Used for                                     triggering from horizontal sync pulses.                                     TV - V: Used for triggering from vertical sync pulses.  Trigger Sensitivity: Internal : 0.5 division (1 division with TV                                       Coupling) External : 500 mV  OTHER SPECIFICATIONS  COMPONENT TEST:  Test Voltage: Max. 6 Vrms (open circuit).  Test Current: Max. 11 mA(shorted).  Test Frequency: Line Frequency  Components : Capacitor, Inductor, Diode, Transistor, Zener etc.  BEAM FINDER: Trace can be return to CRT center area when                                 press beam finder button.  GRATICULE ILLUMINATION: Adjustable  Calibration Voltage: 1 kHz (nominal) Positive                                        Square Wave, 2.0 V p-p (±3%)  Trace Rotation: Electrical, front panel adjustable.  Power Requirements: 115/230 VAC ±10%, 50/60Hz  Dimensions: 324 x 132 x 398 mm (12.8 x 5.2 x 15.6").  Weight: Approximately 7.6kg (16.75bs).  				 					
  
              	
				
 |