Specifications |
GPSU15 Series |
Input voltage |
100-240 VAC (Limits: 90-264VAC) |
Input frequency |
47 to 63Hz (Limits: 47-440Hz) |
Input current |
0.5A (rms) for 115VAC, 0.2A (rms) for 230VAC |
Safety ground leakage current |
0.25mA max @ 240 VAC 50Hz |
Output voltage |
See rating chart (±5% tolerance) |
Output current |
See rating chart |
Output power range |
15 watts Max |
Ripple |
1% peak to peak maximum |
Over voltage protection |
Yes (clamp by Zener diode) |
Over current protection |
Yes (For primary-Referenced Direct Drive) |
Temperature coefficient |
All output ± 0.04% / ℃ maximum |
Transient response |
Maximum excursion of 4% or better on all models. recovering to 1% of final value within 500uS after a 25% step load change |
Operating temperature |
0℃ ~ + 40℃ |
Storage temperature |
-40℃ to + 85℃ |
Relative humidity |
5% to 95% non-condensing |
Derating |
Derated from 100% at+40℃ linearly to 50% at 70℃ |
Efficiency |
65% minimum at full output |
Hold-up time |
5 msec minimum |
Line regulation |
±1% maximum for any input voltage change between input voltage range |
Load regulation |
±5% variations from minimum to maximum output current |
Insulation resistance |
50 Mohm minimum from output to ground |
Inrush current |
15 AMPS @ 115VAC, or 30 AMPS @ 230 VAC at 25℃ cold start |
Withstand voltage |
4242VDC from input to output |
Mean time between failure |
50,000 hours minimum at full load at 25℃ ambient |
EMI requirements |
Meets conduction limits of (a) FCC PART 15 CLASS B (b) CISPR 22.2 |
Safety requirements |
Meets or exceeds: (A) UL 1950 (B) CSA C22.2 (C) TUV EN60950 (D) IEC 950 |
Warranty |
1 year |